Venting; Type Of Vent; Pellet Vent Installation - CASTLE Serenity Instructions D'utilisation

Masquer les pouces Voir aussi pour Serenity:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Venting

Before venting, consult vent manufacturer's specifications and
recommendations for all venting installations.
The following installation guidelines must be followed to ensure
conformity with both the safety listing of this stove and to local
building codes.
Note: Where passage through a wall, or partition
of combustible construction is desired, the
installation shall conform to CAN/CSA -8365.

Type Of Vent

The pellet venting pipe (also known as L vent) is constructed of
two layers with air space between the layers. This air space acts as
an insulator and reduces outside surface temperature of pipe to
allow a clearance to combustibles.
A UL listed 3" or 4" type L pellet vent exhaust system must be used
for installation and attached to the pipe connector provided on
the back of the stove. Use a 3" to 4" adapter for 4" pipe. A cap must
be used at the termination of type L vent chimneys. For elevations
above 2,500 feet above sea level, a 4" L is required.
Pellet Stove Vent Installation
Vent termination MUST exhaust above air inlet elevation.
It is recommended to install at least three feet (3') of vertical
pellet vent pipe. This vertical pipe will create some natural draft
to prevent the possibility of smoke or odor during appliance
shutdown and will keep exhaust from causing a nuisance or
hazard from exposure to high temperatures.
The installation must include a clean out tee to enable collection
of fly ash and to permit periodic cleaning of the exhaust system.
Total length of horizontal vent must not exceed 10 feet. The
maximum recommended vertical venting height is 18 feet.
All joints for pellet vent are required to be fastened with at least
three screws and all pellet vent connections
(including adapters, elbows, etc.) should be sealed
airtight by injecting 500° F. RTV silicone into the
gap between sections.
The area where the vent pipe goes through to the
exterior of the home must be sealed with silicone
or other means to maintain the vapor barrier
between the exterior and the interior of the home.
12
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT DIRECTLY TO A MASONRY
CHIMNEY.
DO NOT TERMINATE VENT IN ANY ENCLOSED
OR SEMI-ENCLOSED AREA, SUCH AS; CARPORTS,
GARAGE, ATTIC, CRAWL SPACE, UNDER A SUN
DECK OR PORCH, NARROW WALKWAY OR CLOSED
AREA, OR ANY LOCATION THAT CAN BUILD
UP A CONCENTRATION OF FUMES SUCH AS A
STAIRWELL, COVERED BREEZEWAY ETC.
VENT SURFACES CAN GET HOT ENOUGH TO
CAUSE BURNS IF TOUCHED. NONCOMBUSTIBLE
SHIELDING OR GUARDS MAY BE REQUIRED.
PELLET
CLEARANCES SPECIFIED BY VENT MANUFACTURER
FOR CLEARANCE TO ANY COMBUSTIBLES.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
ALL
HORIZONTAL, JOINTS SHOULD BE MADE GAS-
TIGHT WITH RECOMMENDED SEALANTS.
Check for parts online at www.castlestoves.com or call 800-450-EDGE (3343) M-F 8-5
Operator's Manual
Serenity Pellet Stove
CAUTION
WARNING
VENT MUST MAINTAIN MINIMUM
VENTING,
WHETHER
VERTICAL
OR

Publicité