Versions Available; Technical Data; Conditions Of Use; Conformity Of The 1062 Atex To Standards And Directives - Burkert 1062 Manuel D'utilisation

Masquer les pouces Voir aussi pour 1062:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technicaldata
5. ATEX certification body and certification number
6. Item number
7. Manufacturing code
8. Conformity Marking
9. Actuator size
10. Mode of operation
11. Limit switch type
12. Operating zone
13. ATEX logo
14. Serial number
15. Temperature classification
5.5

Versions available

To find out about the versions of the position feedback available,
consult the technical datasheet for the 1062 on our Internet site
under:
www.burkert.com
Type 1062
6

TechnicAl DATA

6.1

conditions of use

Ambient temperature
• version approved by CSA and CE
• version only approved by CE
Air humidity
Protection class acc. to EN 60529
6.2
conformity of the 1062 ATeX to
standards and directives
The 1062 ATEX electrical position feedback (version with double
inductive 2-wire NAMUR switch) meets the requirements of the
ATEX Directive 94/9/EC on equipment intended for use in poten-
tially explosive atmospheres. The following standards have been
used in the assessment:
• EN 60079-0 (2004)
• EN 60079-11 (2006)
• EN 61241-0 (2006)
• EN 61241-11 (2007)
english
• 0 to +60 °C
• -20 to +60 °C
< 80%, non condensated
IP65, when wired and
cable gland tightened
11

Publicité

Table des Matières
loading

Table des Matières