1.

INTRODUCTION

Dear customer:
Thank you for choosing a TP3 LN boiler. This manual was written to provide information, warnings and advice on the proper installation, use
and maintenance of the boiler.
Please read it carefully and save it for future reference. It is in your own interest to carefully follow and observe the instructions given in this
manual, in order to fully enjoy this high-quality product.
Failure to comply with and observe the instructions contained in this manual exonerates the manufacturer from all liability, and invalidates the warranty.
2.

GENERAL WARNINGS

- The instructions manual is an integral part of the product, and provides a description of all instructions that must be observed during the
installation, use and maintenance phase.
- This appliance must only be used for the purpose for which it was expressly intended.
- This appliance is intended to heat water to below-boiling temperatures at atmospheric pressure, and must be connected to a cen-
tral heating and/or domestic hot water distribution system, in accordance with its characteristics, performance, and heat output.
- Before installation, check that the boiler has not been damaged during handling and transport.
- The boiler is to be installed on a non-combustible base.
- The boiler is to be installed with a distance of at least 100 mm to any combustible material or component.
- The installation must be performed by duly qualified personnel, in accordance with current standards.
- Before performing any cleaning or maintenance operations, unplug the appliance from the mains power supply.
- THE MANUFACTURER is not liable for any damage to people or things due to errors in installation, adjustment, maintenance, or improper use.
- The boiler and corresponding system must be commissioned by authorized personnel.
- Commissioning is performed in order to verify proper operation of all adjustment and control devices.
- Qualified personnel must be contacted if the appliance is not used for an extended period.
Standards
The installer must observe current local regulations with regard to: the site chosen for the installation of the boiler, compliance with required ventila-
tion conditions, the tightness of the connection to the chimney, connections to fuel lines, electrical systems, and any other relevant safety standards.
Warranty conditions
The warranty is only valid if the standards and recommendations for use contained in this manual are observed. Any non-compliance or modifi-cation will void
the warranty. The warranty does not cover damage caused by acidic condensate corrosion from the products of combustion, or the formation of deposits caused
by the use of hard or aggressive water, as these are caused solely by system operation.
3.

CERTIFICATION

The CE marking certifies that the products meet the essential requirements of the GAR regulation and other applicable directives.
The declaration of conformity may be requested from the manufacturer.
PRODUCT IDENTIFICATION CODES
TP3 LN 70
TP3 LN 92
TP3 LN 107
TP3 LN 152
TP3 LN 190
TP3 LN 240
PAESE DI DESTINAZIONE: ES - IT - FR - RU
4.

TECHNICAL AND CONSTRUCTIONAL SPECIFICATIONS, DIMENSIONS

4.1 Description of the appliance

The construction of the TP3 LN series boilers guarantees high output and efficiency at low flue gas temperatures, thus ensuring reduced pollu-
ting emissions. The appliances are made according to the EN 303 standard, part 1.
The main technical elements of the design are:
- the careful design of the shapes, to ensure an optimum ratio between the combustion volumes and the heat exchange surfaces
- the choice of materials used, for the long life of the boiler.
The boilers use pressurised combustion, with three flue passes, overlapping double plating with completely cooled furnace on the bottom part
and the tube bundle on the top part, and featuring turbulators to create a swirling path that increases the heat exchange by convection.
On leaving the tube bundle, the flue gas enters the rear chamber and is transferred to the chimney.
ORD099XA
TP3 LN 320
ORD000XA
TP3 LN 401
ORD100XA
TP3 LN 500
ORD200XA
TP3 LN 600
ORD300XA
TP3 LN 720
ORD400XA
TP3 LN 820
cod. 3545458/0 - 10/2019
ORD600XA
TP3 LN 940
ORD800XA
TP3 LN 1060
ORDB00XA
TP3 LN 1250
ORDD00XA
TP3 LN 1480
ORDE00XA
TP3 LN 1890
ORDF00XA
TP3 LN 2360
ORDG00XA
ORDH00XA
ORDJ00XA
ORDL00XA
ORDP00XA
ORDS00XA
31
EN

Publicité

Table des Matières
loading

Table des Matières