5.7 Assembling the burner (Fig. 9)
The assembly of the burner to the door of the boiler must ensure perfect tightness to the products of combustion.
Once having installed the burner on the boiler, the space between the burner draught tube and the refractory material on the door must be
filled with the layer of ceramic fibre (A) supplied. This prevents the door from overheating and consequently from being irreversibly deformed.
The fuel connections to the burner must be located so as to allow the complete opening of the boiler door with the burner installed.
Models
L min. (mm)
70-152
230
190-240
250
320-401
290
500-600
320
720-820
320
940-1060
340
1250-1480
340
1890-2360
350
38
EN
8
fig. 8
L max. (mm)
300
320
360
390
390
410
470
480
cod. 3545458/0 - 10/2019
1
2
3
4
8
A
TP3 LN
5
6
7
L
fig. 9