2.6 Connection to the flue

The diameter of the flue connection pipe must not be less than that of the connection on the anti-backflow device.
Starting from the anti-backflow device it must have a vertical section at least 50 cm long. Current standards must
be complied with regarding the dimensioning and installation of the flues and connection pipe.
The diameters of the anti-backflow device collars are given in the table of fig. 2.