Ferroli Pegasus LN 2S Serie Mode D'emploi, Installation Et Entretien page 39

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
Pegasus LN 2S
Pilot light unit
Key
1
Combustion chamber door
2
Inspection door
3
Pilot burner
4
Ignition electrode
5
Detection electrode
6
Pilot nozzle
7
Gas supply pipe
Cleaning the boiler and flue
To properly clean the boiler (fig. 17):
• Turn off the gas ahead of the unit and disconnect the electrical power
supply.
• Take the front panel off the boiler (see Fig. 9).
• Lift the boiler cover by pressing upwards (see also Fig. 3-4).
• Remove the insulation covering the anti-backflow device.
• Remove the fume chamber closing plate and the associated insulation.
• Remove the burner unit (see preceding paragraph).
• Using the brush provided, clean the fume evacuation ducts between
the cast iron elements of the boiler shell, lastly removing the dirt with a
vacuum cleaner.
• Carefully reassemble all the previously disassembled parts and check the
tightness of the gas circuit and the combustion ducts.
Key
1
Screws securing the boiler cover
2
Boiler cover
3
Fume chamber closing plate
4
Fume chamber insulation
5
Brush
6
Combustion analysis plug
EN
fig. 16
fig. 17
Cod. 3540G310 - 03/2007 (Rev. 02)
3 ÷ 4 mm
3
5
7
4
39

Publicité

Table des Matières
loading

Table des Matières