Introduction; General Warnings; Certification; Technical And Constructional Characteristics, Dimensions - Ferroli PREXTHERM RSW 92N Instructions D'utilisation, D'installation Et De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
1.

INTRODUCTION

Dear customer:
Thank you for choosing a PREXTHERM RSW N boiler. This manual was written to provide information, warnings and advice on the proper
installation, use and maintenance of the boiler.
Please read it carefully and save it for future reference. It is in your own interest to carefully follow and observe the instructions given in this
manual, in order to fully enjoy this high-quality product.
Failure to comply with and observe the instructions contained in this manual exonerates the manufacturer from all liability, and invalidates
the warranty.
2.

GENERAL WARNINGS

- The instructions manual is an integral part of the product, and provides a description of all instructions that must be observed during the
installation, use and maintenance phase.
- This appliance must only be used for the purpose for which it was expressly intended.
- This appliance is intended to heat water to below-boiling temperatures at atmospheric pressure, and must be connected to a
cen-tral heating and/or domestic hot water distribution system, in accordance with its characteristics, performance, and heat
output.
- Before installation, check that the boiler has not been damaged during handling and transport.
- The installation must be performed by duly qualified personnel, in accordance with current standards.
- Before performing any cleaning or maintenance operations, unplug the appliance from the mains power supply.
- THE MANUFACTURER is not liable for any damage to people or things due to errors in installation, adjustment, maintenance, or im-
proper use.
- The boiler and corresponding system must be commissioned by authorized personnel.
- Commissioning is performed in order to verify proper operation of all adjustment and control devices.
- Qualified personnel must be contacted if the appliance is not used for an extended period.
Standards
The installer must observe current local regulations with regard to: the site chosen for the installation of the boiler, compliance with required
ventilation conditions, the tightness of the connection to the chimney, connections to fuel lines, electrical systems, and any other relevant
safety standards.
Warranty conditions
The warranty is only valid if the standards and recommendations for use contained in this manual are observed. Any non-compliance or modifi-cation will
void the warranty. The warranty does not cover damage caused by acidic condensate corrosion from the products of combustion, or the formation of depo-
sits caused by the use of hard or aggressive water, as these are caused solely by system operation.
3.

CERTIFICATION

The CE marking certifies that the products meet the essential requirements of the applicable directives.
The declaration of conformity may be requested from the manufacturer.
PRODUCT IDENTIFICATION CODES
PREXTHERM RSW 92N
PREXTHERM RSW 107N
PREXTHERM RSW 152N
PREXTHERM RSW 190N
PREXTHERM RSW 240N
COUNTRIES OF DESTINATION: ES
4.

TECHNICAL AND CONSTRUCTIONAL CHARACTERISTICS, DIMENSIONS

4.1 Description of the appliance

The construction of the boilers in the PREXTHERM RSW N series guarantees high power and efficiency with low flue gas temperatures,
thus ensuring low polluting emissions. They are manufactured in accordance with standard EN 303, part 1. The main technical elements
of the design are:
- careful design of geometries to achieve an optimum ratio between combustion volumes and heat exchange surfaces.
- the choice of materials used, to ensure long boiler life.
The boilers feature pressurized combustion with 2 flue passes, a horizontal-cylinder configuration, and flame reversal in the furnace, com-
pletely surrounded by the water that cools it. The flame produced by the burner is reversed peripherally toward the front, where the flue gas
enters the tube bundle, featuring turbulators to create a swirling path that increases the heat exchange by convection. On leaving the tube
bundle, the flue gas enters the rear chamber and is transferred to the chimney.
38
EN
1B8000921
PREXTHERM RSW 300N
1B8001071
PREXTHERM RSW 350N
1B8001521
PREXTHERM RSW 401N
1B8001901
PREXTHERM RSW 525N
1B8002401
PREXTHERM RSW 600N
PREXTHERM RSW N
1B8003001
PREXTHERM RSW 720N
1B8003501
PREXTHERM RSW 820N
1B8003991
PREXTHERM RSW 940N
1B8005251
PREXTHERM RSW 1060N
1B8006001
1B8007201
1B8008201
1B8009401
1B8010601
A73020801

Publicité