Télécharger Imprimer la page

Refrigerant Material Safety Data Sheet; Wiring Diagram - Sagi KP8G Manuel D'utilisation Et D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
The appliance is excessively noisy
Some condensation is produced on the
appliance
Upon completion of the above checks, if the fault persists, contact an authorised service centre. Always
indicate:
the nature of the fault
the model and the serial number of the unit can be found on the electrical specifications plaque, located
on the unit's instrument panel.

REFRIGERANT MATERIAL SAFETY DATA SHEET

R290
GWP = 3
ODP = 0
❖ Hazards identification
Liquefied gas - Extremely flammable
❖ First aid measures
• Inhalation:
In high concentrations may cause asphyxiation. Symptoms may include loss of mobility and/or
consciousness. Victims may not be aware of asphyxiation. In low concentrations, may cause narcotic
effects. Symptoms may include dizziness, headache, nausea and loss of coordination. Remove victim to
an uncontaminated area wearing self contained breathing apparatus. Keep the patient relaxed and warm.
Call a physician. Apply artificial respiration if breathing stops..
• Contact with skin and eyes:
In case of spillage, rinse thoroughly with water for at least 15 minutes
• Ingestion:
Route of exposure unlikely
❖ Ecological information
No known ecological damage caused by this product
The instruction handbook contains a wiring diagram on the last page.
P
OS
DESCRIPTION
1
COMPRESSOR
2
COMPRESSOR FAN
3
GENERAL TERMINAL BOARD
8
PLUG
9
EVAPORATOR FUN
12
SOLENOID VALVE DEFROSTING
20
DOOR ANTICONDENSING RESISTOR
20A
SIDE GLASS ANTICONDESATION RESISTANCE
HEATER
SIDE GLASS ANTICONDESATION RESISTANCE
20B
HEATER
REAR GLASS ANTICONDESATION RESISTANCE
20C
HEATER
SECTION ANTICONDENSATION RESISTANCE
20D
HEATER
22
RESISTANCE FOUND BASIN
22A
RESISTANCE HEATER EXHAUST PIPE
Check that the appliance is standing level. A lopsided appliance could set
off vibrations
Check that the appliance is not touching other appliances or parts which
could resonate
Room humidity is very high
The door is not closed properly

WIRING DIAGRAM

P
OS
DESCRIPTION
44
RELAY COMPRESSOR
69
GROUNDING TERMINAL
70
COLD DELIVERY SOLENOID VALVE
70A
WARM DELIVERY SOLENOID VALVE
76
MAGNETIC MICRO-SVWITCH
103
HUMIDITY SENSOR
119
TN DISPLAY CASE ELECTRONIC DATA CARD
120
BT DISPLAY CASE ELECTRONIC DATA CARD
121
LED SWITCHING POWER SUPPLY
122
LED LAMPS
122A
TOP LED LAMPS
125
ELECTRONIC DATA CARD PRALINERY DISPLAY
CASE
126
CAPACITIVE BUTTONS DISPLAY BOARD
28