Télécharger Imprimer la page

High Temperature Alarm - Sagi KP8G Manuel D'utilisation Et D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
The inner fan operates according to the value given to parameter "F3".
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
Humidity sensor Error (only on +14°C/+16°C units)
In the event that the humidity sensor is broken or its connection is interrupted on the display the label [E8], is
visualised; the humidity control device is automatically deactivated.
Condenser probe error
If the condenser probe is broken or the relevant connection interrupted, the display shows the label [E2].
The condenser fan keeps operating according to the value given to parameter "F8".
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
UNIT WITH BROKEN SENSOR PROBES DURING DEFROST
Room probe error
In the event that the chamber sensor probe is broken or the respective connection has been interrupted
during the defrost phase the function will be completed normally.
The string set with the parameter "d6" and the label [E0] will be visualised alternatively on the display.
Evaporator fan error (only on -22°C / +5°C units)
In the event that the evaporator sensor probe is broken or the respective connection has been interrupted
during the defrost phase the function will be completed through time out.
The evaporator fan will continue to operate according to the value assigned with the "F4" parameter.
The melting times "d7" and the internal fan activation delay "F5" will be observed in any case.
A display viene visualizzata alternativamente la stringa settata con il parametro "d6" e la label [E1].
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
Humidity sensor Error (only on +14°C/+16°C units)
In the event that the humidity sensor is broken or its connection is interrupted on the display the label [E8], is
visualised; the humidity control device is automatically deactivated.
Condenser probe error
If the condenser probe is broken or the relevant connection interrupted, the display shows the label [E2].
The condenser fan keeps operating according to the value given to parameter "F8".
If the three probes are broken or disconnected, E0, E1, and E2 alternate on the display.
DOORFRAME SECTIONS ANTICONDENSATION RESISTANCE HEATER MANAGEMENT
(only on -25°C / -15°C and -22°C /+ 5°C units)
In the event that the chamber sensor probe is broken or its respective connection interrupted, the machine will
continue to operate managing the activation/deactivation of the door resistance heater in parallel with the
activation/deactivation of the compressor relay.

HIGH TEMPERATURE ALARM

If the room temperature exceeds the setpoint, the label [AH] and the temperature
reached alternate on the display.
Press up to display the duration of the event causing the alarm.
The buzzer can be turned off by pressing the key
The visual alarm signal stays on until the temperature returns within the normal range.
.
16

Publicité

loading