8.1
LED-module replacement
LED-module replacement can be done without cut off the luminaire
from mains supply, because an all pole switch will isolate the
lampholders while opening the protective bowl.
Notice: Observe national standards or directions for use which can be
divergent to this!
The LED-module have to be replaced as shown in fig. 11 and 12.
Fault indicator: eLL. .. NE;
(Test during continuous switching of light fitting - combinations with several faults are not registered)
Operation
Mains
Emergency
See the enclosed operating instructions for eBK12, No. 3 2211 00 172, for further information on the function and fault indication.
Explosion protected emergency light fittings
Series: eLLK(M)(S)92 LED 400A(800A) NE
Mains
Mains / Emergency
Mains OFF
Mains ON
LED row of module OFF
LED row of module ON
9.

Disposal / Recycling

When the apparatus is disposed of, the respective national regulations on
waste disposal will have to be observed.
In order to facilitate the recycling of individual components, plastic parts
are provided with the identification mark of the plastic material used.
In case of disposal you can obtain additional information from your Cooper
Crouse-Hinds / EATON branch.
Subject to modifications or supplement of the product range.
Achtung!
Chemische Beständigkeit beachten.
Nur mit feuchtem Tuch säubern.
Warning!
Do not use chemical cleaner.
Clean with a damp cloth only.
Important!
Attention à la resistance chimique.
Nettoyer uniquement avec un
chiffon humide.
Battery
ok
or
or
ok
VE 12 faulty
VE 12 faulty
ok
V
Battery low
,
Lamp fault
v
Battery fault
v
LED red - green ON
,
LED red, - green flashing
LED red, - green OFF
V V