All cylinders and pressure regulators used in welding operations should be handled with care. If the gas cylinder is not
connected, leave the valve protection in place. Always use gas cylinders suited to various types of application as well
as appropriate accessories (pressure/flow regulators, pipes, fittings, etc.). Only use gas cylinders and accessories in
good condition. If a gas cylinder valve is open, move your face away from the point where the gas emerges. When you
have finished welding or cutting, close the valve of the gas cylinder used. Make sure no inert gas is leaking from the
cylinders. Inert gas is colourless and odourless. An environment saturated with inert gas is devoid of oxygen, which
causes asphyxiation of people in the environment.
Position the cylinder on the support and fix it with the 2 straps; ensure that the straps are secured tightly to the
cylinder to prevent dangerous tilting.
Connect the gas hose to the outlet of the pressure regulator.
Open the side door of the wire feeder.
Connect the earth cable to socket 4 and through the terminal to the workpiece.
Fit the wire coil on the support. The coil must be fitted so that the wire unwinds in an anticlockwise direction.
Make sure the drive roller is correctly positioned according to the diameter and type of wire used.
Cut the welding wire with a well-sharpened tool, keeping it between your fingers so that it cannot unwind, insert
it inside the pipe exiting from the gear motor and, with the aid of a finger, insert it inside the steel tube until it
emerges from the adapter.
Fit the welding torch.
After fitting the coil and torch, switch on the machine, select the appropriate synergic curve, following the
instructions given in the "DESCRIPTION OF FUNCTIONS" section. Remove the gas nozzle and unscrew the
torch contact tip. Press the torch trigger until the wire emerges. BE CAREFUL to keep your face away from
the end lance while the wire is emerging, tighten the contact tip and fit the gas nozzle.
Open the canister adapter and adjust the gas flow to 10 – 12 l/min.