Dimensions in mm
100
X88
GHG 432
100
X88
GHG 434
X = fixing dimensions
Dimensions of operating elements
Pushbutton actuator
Double pushbutton actuator
Mushroom-head pushbutton actuator
"EMERGENCY STOP"
12
Explosion-protected control units GHG 43.
1

Technical data

1.1

Control unit assemblies

90
EU-Type Examination Certificate:
6
Marking acc. to 2014/34/EU and standard:
IECEx type examination certificate:
Category of application:
* depending on the product variant
(with 80 - 110 V DC signal lamp LLD)
Rated voltage:
Rated current:
Permissible ambient temperature:
(Other temperatures possible with special versions)
Perm.storage temperature in original packing:
Degree of protection to EN/IEC 60529:
90
6
Insulation class acc. to EN/IEC 61140:
PE- terminal:
Terminals:
Cable entries (catalogue version):
suitable cables and test torques of the pressure screw
Cabel entry:
seal 1+2+3
(Ø mm / Nm)
seal 1+2
(Ø mm / Nm)
seal 1
(Ø mm / Nm)
Test torque for screw in thread cable entry (Nm) 1.2
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can vary by
using cables with different manufacturing tolerances and material properties. Please use a suitable combination of
seals in the intermediate area, so that the cap nut can be tightened in future maintenance work on the cable entry
Empty weight:
Control unit GHG 432
Control unit GHG 434
Test torques:
Cover screws
1.2

Actuator general

EU-Type Examination Certificate:
Marking acc. to 2014/34/EU
and standard of series EN 60079:
IECEx type examination certificate:
Category of application
standard of series IEC 60079:
Operating temperature:
EN 60079-0
IEC60079-0
min.
1 2
3
(1)
max.
min.
1 2
3
(1)
max.
min.
1 2
3
(1)
max.
II 2 G ... IIC
II 2 G ... IIB
II 2 G ... IIB+H2
PTB 00 ATEX 3117
II 2 G Ex d*e*ib*mb*IIC T6 Gb
II 2 D Ex tb IIIC T80°C Db
IECEx BKI 04.0003
Ex d*e*ib*IIC T6
T4
up to max. 500 V
max. 16 A
-20 °C ... +40 °C (standard version)
-20 °C ... +40 °C
IP 66 (standard version)
IP 65 double pushbutton
I – with metal flange
II – plastic terminal boxes fulfil this requirement
2 x 4 mm²
see built-in components
2 x M25
(1 x M25, 1 x with blanking plug)
M12
M16
M20
M25
8.0 / 1.5
10.0 / 2.0
5.5 / 1.0
7.0 / 1.5
10.0 / 2.3
7.0 / 1.0
9.0 / 1.4
13.0 / 2.6
5.0 / 0.8
7.0 / 1.0
9.5 / 1.0
13.5 / 1.3
13.0 / 1.7
17.5 / 2.3
7.0 / 1.0
10.0 / 1.4
3.3
2.7
3.0
approx. 0.47 kg
approx. 0.70 kg
2.00 Nm
IBExU14ATEX1030U
II 2 G Ex db eb IIC/IIB/IIB+H2 Gb
I M 2 Ex db eb I Mb
IECEx IBE 14.0005U
Ex db eb IIC/IIB/IIB+H2 Gb
Ex db eb I Mb
-55 °C
...
+80 °C
-60 °C
...
+80 °C
-55 °C
...
+80 °C
GB
M32
14.0 / 3.0
17.0 / 4.0
17.5 / 1.5
21.0 / 1.3
5.0
.