Replacing The Electrical Cable - De Dietrich TEPPAN YAKI Mode D'emploi Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• If the connection is not performed using an electrical outlet, contact an electrician
who is familiar with the local regulations and additional rules issued by the local
power company and who can perform the work in compliance with the same.
• If the socket is no longer accessible after recessing or if a fixed connection is
provided, a separation device must be prepared for each pole by the installer. The
circuit breakers that ensure disconnection from the network, with a contact opening
distance that allows complete disconnection in the conditions of category III, , in
accordance with the installation rules, are used as separation devices.
• Data required for connection can be found on the data plate whose information
must correspond to the mains supply (1.1.11).
• The power cord MUST NOT:
- be crushed orrolled up on itself,
- be extended with extensions,
- come into contact with sharp or hot objects, with liquids of any kind, and
corrosive substances.
Differential switch (circuit breaker)
For greater safety, it is advisable to set up a differential circuit breaker (circuit
breaker) with a trip current corresponding to 30 mA. With 100 mA protection, after
prolonged shutdown of the device the differential circuit breaker may trip.
Disconnect the appliance from the power supply
To disconnect the appliance from the mains, depending on the installation, proceed
as follows:
– Fuses: completely remove the fuses from the threaded caps
or
– Automatic protections press the control button (red), until
the central button (black) comes out
or:
– Recessed protections: (automatic switch at least of type B or C):
bring the lever from 1 (insertion) to 0 (disengagement)
or:
– Automatic differential switch (circuit breaker): bring the main switch
from 1 (on) to 0 (off) or press the control
button.
After disconnecting, make sure that the power supply cannot be reinserted.

Replacing the electrical cable

If it is necessary to replace the connecting cord because it is damaged, use an
electric cord type H05GG-F or H05SS-F 3x1.5mm² available from the technical
assistance service (1.1.12).
Replacement must only be carried out by the manufacturer, by the technical
assistance service or by a qualified electrician.
The connection data is shown on the serial number plate.
15
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Dpe7400x

Table des Matières