Rooftop Air Conditioning System Citysphere
– Remove adhesion remainder and clean new adhesion surface.
4.8.

Adhesive bonding of the unit

The first unit in front in direction of travel should be the master unit (recognizable by control and temperature
sensor). Condenser pointing to direction of travel.
The other units are slave units, and are controlled by the master unit.
– Place unit, put it in the center and draw.
The radius of the roof hatch cutout doesn't match necessarily with the
contour of the adhesion surface of the baseplate. Therefore it is advisable
to transfer the inner contour of the baseplate to the roof of the bus.