INSTALLATION

4.1.

Safety instructions

The safety instructions set out in chapter 1.3 must be read and noted before starting work.
Installation should be performed by someone well versed in auto mechanics/auto electrics.
4.2.

Conditions for assembly

– Before assembling and operating the air conditioning system(s), the vehicle's power supply must be
checked for sufficient capacity, and must be upgraded if necessary.
A free generator capacity of 72 A (max. current consumption per unit) must be at disposal per unit to be
constructed.
This capacity must be guaranteed at idle speed, and at the same time at maximum engine compartment
temperature (low speed and high ambient temperature diminish the output of generators).
– Existing roof hatch cut-out per unit to be installed 530/564 x 970 mm.
– The required number of escape hatches according to the operating license, may not be reduced by the
units to be constructed.
4.3.

Installation kit for master unit

– rooftop air conditioning unit master
– air-diffusor
– fastening set
– control panel + cable
4.4.

Installation kit for slave unit

– rooftop air conditioning unit slave
– air-diffusor
– fastening set
– Adapter cable to preceding unit (master or slave)
4.5.

The following are not included in the installation kit and must be produced on site

– Connecting cables and elements (vehicle side)
– Fastening elements for routing the connecting cables
– Fuse brackets and fuses to protect connecting cables
– Fuse bracket and fuse to connect the distribution panel to terminal 15
– Adhesion (Sika 252), cleaner (Sika Cleaner 205), activator (Sika Primer 215), sand paper
– Foam for sealing the air gap between roof and inner ceiling, circulating the unit (to avoid an air short-
circuit) with the following qualifications:
– closed cellular
– little absorption of water
– Fire behavior according to FMVSS 302 resp. 95/28/EC attachment IV
For example: D2600 from Cellofoam
– Possibly necessary additional generators with installation kit
Rooftop Air Conditioning System Citysphere