BWP 30HS - BWP 30HSD
Display
2nd heat generator
2nd heat generator (HG 2)
Bivalence temperature         
Ventilation
Ventilation
Photovoltaic
Photovoltaic
Setpoint
EN-10
Description
Activates a 2nd heat generator (e.g. oil or gas boiler). If solar operation
is not being used, the 2nd heat generator can be activated. Priority is
given to the activation of the flange heater if the lower operating limit or
the bivalent temperature is undershot.
Limit temperature for 2nd heat generator. The heat pump is blocked
below this temperature
**(BWP 30HS down to 8 °C, BWP 30HSD down to -8 °C)
Activates the ventilation function. Continuous operation of the fan is
also possible independent of domestic hot water preparation in order
to ensure air circulation or an exhaust air function. The speed and thus
the volume flow can be set as a percentage. 100% corresponds to a
volume flow of 450 m³/h. 0% means that the fan is switched off outside
of domestic hot water preparation.
Activates the photovoltaic function. The digital input is evaluated after
the photovoltaic function is activated (see Cap. 7.3.6 on pag. 12 for fur-
ther information)
Entry of the domestic hot water setpoint, which is active when photo-
voltaic inlet A3-1 - A3-2 is wired.
The increased setpoint is also active if the air intake temperature does
not allow the heat pump to operate. In this case, the request is proc-
essed with the electric heating element or, where present, the 2nd heat
generator.
451903.66.11 · FD 9401
Setting range
Yes
No
- 8 / 8**
....
15
20%
....
100%
Yes
No
35 °C
...45 °C...
60 °C