Menu Structure - Dimplex BWP 30 HS Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2 Menu structure

Parameter change: The menu is accessed using the
this menu, changes can be made to parameters. The desired
menu item is selected using the
marked with the cursor symbol
using the
key.
Display
Settings
Time
Weekday
Language
Domestic hot water
Setpoint
Hysteresis
Min. temperature
Time programs
HP block
Time
Day
Thermal disinfection
Time
Setpoint
Day
Solar
Switch-on diff.
Switch-off diff.
Max. tank temperature
Max. collector temperature
www.dimplex.de
key. In
and
keys, which are
. The submenu is accessed
Description
Sets the current time
Sets the current weekday
Sets the desired language
Sets the desired domestic hot water setpoint
Sets the switching hysteresis
Sets the minimum domestic hot water temperature, which should also
not be undershot for the duration of a programmed shut-off time.
Sets the start and end time for a heat pump block
Sets the weekday / block of days on which the heat pump block should
be activated
Sets the start time for thermal disinfection
Sets the set temperature for thermal disinfection. The flange heater is
also used additionally for this function
Sets the day on which thermal disinfection should be activated
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched off
Sets the maximum cylinder temperature that is permissible when solar
gain is available
Sets the maximum permissible temperature on the collector
451903.66.11 · FD 9401
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The value to be changed is
displayed in "bold" using the
using the arrow keys. The entry is completed by pressing the
key again.
BWP 30HS - BWP 30HSD
key, and can then be changed
Setting range
00:00
Mo
....
Su
EN
EN
FR
25
...45 °C...
60
2
...3K...
10
15
...25 °C...
40
00:00 -
00:00
Mo - Su (day)
Mo - Fr (block)
Sa - Su (block)
Mo - Su (block)
00:00:00
60
...65 °C...
(65 °C)
Mo - Su (day)
Mo - Fr (block)
Sa - Su (block)
Mo - Su (block)
6
...8...
10
2
...4...
6
60
...65 °C...
85
125
...130 °C...
135
EN-9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bwp 30 hsd

Table des Matières