Troubleshooting
Solar Controller Errors
Error representation on
display
Flashing
Flashing
Error representation
no display function
Solar Controller does not work
Symbol "pump" rotates, but pump
does not work
Temperature display varies strong
in short time intervals
All manuals and user guides at all-guides.com
Possible Cause
Sensor wire broken
Defective sensor
Short circuit in sensor wire
Defective sensor
Possible Cause
Lost main power
Controller internal safety fuse failed
Appliance defect
Solar Controller is in manual opera-
tion
no demand for unit to be on
Loose wiring
Interference from neighboring wires
Long sensor wires lengthened without
shielding
Controller or Sensor defect
Corrective Measures
Check wire
Check sensor resistance, if necessary
replace sensor
Check wire
Check sensor resistance, if necessary
replace sensor
Corrective Measures
Check to ensure that circuit breaker
has not tripped
Check other 120V components on
circuit to see if they are working
Check safety fuse in controller, replace
it by a new one, type 2A/T, if necessary
Consult installer
Exit menu "Manual operation"
Wait until temperatures place demand
on system to turn on
Check pump(s) wiring connections
Consult Installers
Adjust location of wires
Shield Sensor Wires
Consult Installers