4.6- Start-up
Warning! The pump should be filled with water after each new connection or in the event of water loss
or air intake. Extended operation without a water refill (unsupervised dry run) will destroy the pump.
Unscrew priming screw (2).
Fill completely with water (do not splash electrical components with water).
Reinstall priming screw.
If the water level drops in the body or if the discharge is not performed correctly, it may be caused by an
air intake. In this case, check the suction pipe connection and proceed again with filling body.
If you want to shorten the intake time, fill the suction line as well (only possible with a check valve).
Switch the pump on.
Open pressure line (turn on water spigot or nozzle), so that air can escape during intake.
When water runs out evenly, turn the pump off. The pump is ready for use.
If the water does not flow and the pump does not suck water, make sure there are no leaks in the pump
body, pipes and fittings.
V. OPERATION
5.1- Intended use
- JET pump (alone or in a booster group) is designed to draw clear water.
- It must be installed in a dry, ventilated place, protected from weather and excessive heat.
- The maximum suction height should not exceed 7 meters.
- Properly installed, your pump will operate with maximum efficiency and will give you complete
satisfaction.
- The pump is designed for routine household uses such as gardening, irrigation systems, increased water
pressure distribution in non-food, pumping water tanks...
- The pump must not be used for operations not described in this manual.
It should not be used in particular for:
- pumping seawater, waste water, water containing solids, sand or abrasive particles in suspension, water
containing corrosive substances in general.
- pumping water having a temperature above 35°C.
- pumping of explosive, flammable or dangerous liquids.
- pumping water intended for human consumption or food liquids.
NOTE:
- This pump is not intended for cleaning and other pool maintenance operations.
- The pump must not be used in outdoor fountains, garden ponds and similar places.
- The pump is not designed for industrial and / or commercial applications (eg, in public parks, sports
fields ...).
Additional information for booster pump
The booster optimizes the water supply by limiting repeated on/off, and especially allows maintaining a
constant pressure in the system.
5.2- Operation
- Proceed with the suction and discharge lines connections described in chapter 4 above.
- Press the on / off switch.
- The pump turns on when you open the terminal (e.g. water tap, spray gun...)
Page 15 / 15