3. The supply cable should be checked periodically and before each use to see if there are any signs of
ageing or damage.
If the pump is not in good condition, do not use it. Have it repaired by an authorized centre.
4. If an extension is used, ensure that it is officially approved. Keep it well away from sharp edges, heat
sources and combustibles.
5. The plug-in connector for the extension should be of the 2 pole + earth type of 10-16A/250V, in
accordance with EEC standards. The wire section in the cable should be equal to or greater than 1mm
2
.
The cable should not be lighter than cables of H07 RN-F.
6. When disconnecting the power cable from the socket, always grip the plug itself and not the cable.
7. If the pump is used for emptying a pond, it should not be used when there are people in the pond.
Similarly, to avoid accidents during pump operation: washing, swimming or domestic animals bathing is
strictly forbidden around the operating area.
8. Do not transport, carry or hang the pump by its cable, use the carrying handle.
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage
4.2- Important recommendations
Before connecting to the power source, you must observe the following:
- The device must be placed on a horizontal, leveled surface that is sufficiently capable of supporting the
total weight of the device when filled with water.
- Make sure that the power supply corresponds with the connection specifications of the device (see rating
label).
- To prevent vibrations, the device should be placed on an elastic support (e. g. a rubber mat).
- The installation site must be well ventilated and protected from the effects of weather.
- When being used near garden ponds and swimming pools, the device must be set up so as to guard
against overflowing and protected against falling in.
- Additional legal requirements must be observed
- When operating indoors you must ensure that there is a drain in the floor or a leak prevention
mechanism.
- Before starting up, check the suction hose to ensure that it is sealed. Bubbles of air in the suction hose
are an indication that there may be leaks and may lead to failure of the device.
WARNING!
- The warranty does not cover accidents due to improper installation. This pump must be installed in
accordance with local standards and by a qualified person (we recommend you to contact an electrician).
- The fixed pipeline that will connect the pump must include a separation device having contacts with the
opening distance of at least 3 mm in all poles.
- It is recommended that the device be connected with a residual current of not more than 30 mA by means of a
residual-current-operated protective device
- The total head must not exceed 30 m.
2
2
- The cable must be at least one cable H07 RN-F 3×1mm
(or exceed 1mm
) (line, neutral and earth).