Capacitive Load Boundary for Constant Voltage (CV) Operation

The following figures show the boundary limitations for capacitive loads with equivalent series
resistance (ESR) for constant voltage operation. Operation below the red marginal stability lines with
the
Compensation
bandwidth settings may result in output instability. There are no absolute limits for
DUT capacitance, as the stability is also a function of ESR. Refer to
Load Capacitance and Lead
Inductance Considerations
for details.
For 20 kW Models RP7971A, RP7972A, RP7973A
Capacitive Load Boundary (500 V units)
56
Keysight RP7970 & RP7980 Series Operating and Service Guide