Technical Data; Relative Humidity - Abicor Binzel ABIPLAS CUT Mode D'emploi

Torches de coupage plasma
Masquer les pouces Voir aussi pour ABIPLAS CUT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
ABIPLAS
CUT

3.1 Technical data

Cutting
Transport and storage

Relative humidity

Tab. 1
Ambient conditions during operation
®
Type ABIPLAS
CUT
Type of use
Type of voltage
Operating mode
Max. arc ignition and
stabilisation voltage
Breakdown voltage 50 Hz
Voltage rating
Protection type of the device connections
(EN 60529)
Type of cooling
Minimum/Maximum value for gas
pressure
Control device in torch handle
Tab. 2
General torch data (EN 60974-7)
NOTICE
• P < 4.8 bar will result in the thermal overload of the torch!
Type
Type of use
Pilot current
Rated current and
corresponding duty cycle
Type of gas
Gas flow rate
Tab. 3
Product-specific torch data (EN 60974-7)
BAL.0099 • 2021-08-20
–10°C to +40°C
–25°C to +55°C
Up to 90% at 20°C
®
ABIPLAS
CUT 70
®
ABIPLAS
CUT MT 70
15–22 A (max. 25 A)
70 A / 60%
50 A / 100%
Approx. 155 l/min
70/110/150
Manual
DC direct voltage
Single gas torch
7 kV
Peak value of 500 V
IP3X
Air-cooled
min. 4.8 bar/max. 7.0 bar
42 V/0.1–1.0 A
®
ABIPLAS
CUT 110
®
ABIPLAS
CUT MT 110
Manual/automatic
15–25 A (max. 27 A)
110 A / 60%
90 A / 100%
Compressed air
Approx. 180 l/min
3 Product description
MT 70/MT 110/MT 150
Automatic
IP2X
®
ABIPLAS
CUT 150
®
ABIPLAS
CUT MT 150
15–27 A (max. 29 A)
150 A / 60%
120 A / 100%
Approx. 235 l/min
EN - 5

Publicité

Table des Matières
loading

Table des Matières