After the unpacking of the item from its packing, proceed by removing the adhesive plastic
tape before sarting up the product. Any residual glue has to be removed carefully (do not
use abrasive cleaners).
The device is designed to run on AC to the voltage specified on the technical data plate
(located on the bottom of the tank).
The grounding line is marked by the colours yellow/green and must not be interrupted.
The device is provided with a cable in accordance with the CE regulations and with a
schuko plug (that can be replaced, when necessary, with a different plug, suitable for the
specified wattage and in accordance to the current regulations and guidelines; when
necessary, replace the provided cable with a new one with the same features).
Before switching the appliance
Check if the electrical system can withstand the appliance's load (WATT as indicated
on the technical plate)
Make sure that the electrical system is provided with ground connection according to
the current norms and guidelines.
Connect the appliance with the ground network through a cable connected to the
specific screw placed on the external casing of the appliance (See Component n°15
page. 6).

4.1 Appliance Start Up

Once ready to switch on the appliance, plug the device in the electrical system and press
the power switch placed on the compressor front grid.
You will hear a soft buzzing coming from the compressor and the thermostat display will
show the starting temperature of the device.
Once started up, the appliance reaches the selected temperature in about one hour (it
depends much on the starting temperature, the room temperature and the exposure of the
buffet trolley).
The thermostat is set from the manufacturer on +2°C for a optimal use of the device. Use
the attached instructions to change the settings of the digital thermostat.
CAUTION! Any change in the thermostat settings must be done on the
temperature only. Any other parameter changes can affect and damage
the operation of the compressor
PLEASE REFER TO THE ATTACHED INSTRUCTIONS