ADVICE DURING INSTALLATION AND ASSEMBLY OPERATIONS.
During the connection operations of the electrical wiring to the valve modules, great attention must
be given to polarity, and it must be verifi ed that pieces of wiring are not left inside after closing.
Make all connections by following the instructions in this manual.
It should be verifi ed that the electrical wiring connections to the valves electronic card are fi rmly
made.
The seal on the module's box should be checked for correct positioning to prevent the entry of water,
it should also be checked that the compression gland is also correctly located
Particular attention should be paid, so that, under no circumstances, is it possible for water to
enter the electronic module. In the case where the intended use is not that for which the valve was
designed, adaptation and supplementary technical regulations may be necessary.
ADVICE FOR WHEN PUTTING INTO SERVICE.
Before putting the automatic valve into service, it is necessary to verify the calibration of the
electrical protection devices in the operations cabinet and that they are correctly positioned and
fi xed in place.
NOTE: It is recommended that the bathing facilities are not used while the fi ltration equipment
is in operation.
ADVICE DURING INSTALLATION AND MAINTENANCE WORK.
National installation regulations must be taken into account when assembling and installing the
automatic valve.
Extra care must be taken so that it is not possible, under any circumstances, for water to enter the
automatic valve electronic circuit.
All contact, including accidental, must be avoided at all times with the moving parts in the automatic
valve during operation and/or before complete shutdown.
Before carrying out any maintenance or any other electrical or electronic work, it must be ensured
that switch-on devices are locked.
It is recommended that the following steps be taken before performing any maintenance on the
automatic valve.
1.-
Remove electrical power to the valve.
2.-
Lock the switch-on devices.
3.-
Verify that there is no electrical power being applied to the circuits, including auxiliary
and supplementary services.
This list must be considered indicative and not binding with respect to safety, there may be other
specifi c safety standards in particular regulations.
IMPORTANT: due to the complexity of the situations covered, the instructions for installation, use
and maintenance contained in this manual, do not make any attempt to cover all possible service
and maintenance cases. If additional instructions are necessary or specifi c problems arise, please
do not hesitate in contacting the distributor or the valve manufacturer directly.
Our automatic valves may only be installed in swimming or other pools which fully comply with the
HD 384.7.702 standard. When any doubt exists a specialist should be consulted.
Please check the packing contents.