en Installation instructions
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
12.7 Information on the installation situation
¡ Install this appliance in a kitchen cupboard.
¡ To install additional special accessory parts, obser-
ve the enclosed installation instructions.
¡ The appliance must be installed with no more than
one side directly next to a high-sided unit or a wall.
The distance between the appliance and wall or
high-sided unit must be at least 50 mm.
12.8 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ Use an exhaust pipe that is made of non-combusti-
ble material.
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
12.9 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
12.10 Information about circulating-air
mode
The appliance must only be operated when it is se-
curely installed and the pipework is connected.
12.11 Installation
Checking the unit
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The max. weight of the appliance is 10 kg.
Ensure that the fitted unit is heat-resistant up to
2.
90 °C.
28
Ensure that the fitted unit is still stable after the cut-
3.
outs have been made.
Preparing the units
Requirement: The unit is suitable for the installation.
→ "Checking the unit", Page 28
Make the cut-out for the appliance.
1.
Make the cut-out for the exhaust air pipe either
2.
above the fitted unit or behind the fitted unit.
Preparing the appliance
Fit the one-way flaps on the air outlet and click them
1.
into place.