If the fire in the gas hearth has gone out you must wait at least 10 minutes before reigniting the
gas stove (check the section on 'putting the fireplace into operation).
To ensure safe and correct operation of the fireplace it is advisable to have it checked and cleaned
by a certified installer at least once a year.
If the fire in the fireplace extinguished repeatedly you must consult your installer.
The front side of the stove is regarded as the heat exchange surface.
Caution: do not burn the stove if the glass window is broken or if the door of the stove is open.
Have the hearth repaired only with original parts supplied by the manufacturer, and have the
repairs carried out by a certified installer.
Do not alter or add anything to the log set under any circumstance. If a log is broken it must be
replaced by an original log that is supplied by the manufacturer.
To eliminate any possible risk of fire, the distance between the combustible parts and the furniture
must be at least 100cm, and the distance between the rear side of the stove and the wall must
be at least 20cm.
It is important that you do not use the fireplace shortly after renovation or in a newly built home;
the air circulation draws in moisture and unhardened volatile elements of plaster, paint, floor
coverings and other materials. This can cause soot stains on cold surfaces.

3.5 TTB Safety device

The fireplace is equipped with a thermal reflux safety valve (TTB), a temperature switch that becomes
operative when the chimney does not draw well and flue gasses enter the room. When this happens,
the unit will conk out.
Caution: Never put the TTB out of operation. When the TTB is defect, you must replace it with
original parts.
When the TTB safety mechanism has shut off the stove, you must wait at least 10 minutes before
lighting the fireplace again. If the burner conks out repeatedly, you must consult an installer.
Caution: Do not use the fireplace until the qualified installer has given the go-ahead.

3.6 Operating the fireplace for the first time

When lighting the fire for the first time, an unpleasant scent may develop caused by the hardening of the
heat resistant lacquer on the stove. The scent will disappear after several hours. We therefore advise
you to burn the stove at its highest capacity when you light up the fire for the first time while ventilating
the room in which the stove is installed.

3.7 Maintenance

In order to ensure the safe and correct operation of the fireplace, the stove must be checked and
cleaned by a qualified professional every year. The service should include the burner unit, the pilot
flame and the combustion chamber.
The ceramic glass can be cleaned with a special cleaning agent for ceramic cookers.
If a log is broken it must be replaced.
If there is a crack in the glass window, or if the window is broken, it must be replaced before operating
the gas hearth.
When the logs are replaced, ensure that they are placed in the correct position (see the chapter on the
log set).