Antenna Installation - BFT HYDRA R Instructions D'utilisation Et D'installation

Centrale de commande pour commander 1 ou 2 opérateurs de la série phebe, conçus pour motoriser des portes de garage de type différent
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
ENGLISH
-
3 Steps/4Step (3 step) [ OFF ]
ON
Enables 3-step logic. stops and reopens
OFF Enables 4-step logic.
-
Impulse lock (ibl open) [ OFF ]
ON
Enables impulse lock during the opening phase.
OFF Excludes impulse lock during the opening phase.
-
Photocells on opening (photoc. open) [ OFF ]
ON
Enables on closing phase only.
OFF: Enables on opening and closing phase.
-
Photocell test (test phot) [ OFF ] (Advanced logics - address 14)
ON
Activates the safety device checking function (Fig. 3b)
OFF Deactivates the safety device checking function (Fig. 3d).
-
Gate-open or 2nd radio channel warning light (sca 2ch) [ OFF ]
ON
The output between terminals 21 and 22 is configured as Gate-open
warning light.
OFF The output between terminals 21 and 22 is configured as 2nd radio
channel.
-
Lock hold (block persist) [ OFF ] (Fig. 5)
ON
To be used when the mechanical closing backstop is fitted.
This function activates leaf pressure on the mechanical backstop,
without this being considered as an obstacle by the Ampere-stop
sensor.
Therefore the rod continues its travel for another 0.5 sec. after detecting
the closing limit switch or upon reaching the mechanical backstop. So
by activating the closing limit switches slightly earlier, the leaves will
come to a perfect halt against the backstop.
(Fig. 5a)
OFF To be used when no mechanical closing backstop is fitted.
Movement is exclusively halted by activation of the closing limit
switches; in this case proceed to carrying out precise setting of the
closing limit-switch activation. (Fig. 5b)
-
Prealarm (Pre AL) [ OFF ]
ON
The blinker comes on about 3 seconds before the motors start
OFF The blinker comes on at the same time as the motors start
-
Fixed code (Fixed code) (OFF) (Advanced logics - address 13)
ON
Activates the incorporated receiver to fixed-code mode.
OFF Activates the incorporated receiver to rolling-code mode.
(see paragraphs 11.1 and 11.2)
-
Radio transmitter programming (radio prog) [ OFF ]
(UNIPRO ⇒ Advanced logics ⇒ address 15)
ON
This enables transmitter storage via radio:
1 - First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 - Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new tran-
smitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio
menu.
-
Loop (loop) [ OFF ] (Advanced logics - address 11)
ON
In the case of a closed loop centralised connection (Fig.5), set the
control unit to ON.
OFF In the case of an open centralised connection (Fig.5), set the control
unit to OFF.
-
Master/Slave (Master) [ OFF ] (Advanced logics - address 12)
ON
The control panel is set as Master in a centralised connection.
OFF The control panel is set as Slave in a centralised connection.
-
Logic 1 (lg1) [ OFF ]
ON
The following manoeuvre to be activated will be used as Autoset (for
this to happen it is necessary that the manoeuvre starts from the
closing end of stroke). At the end of this manoeuvre the "LG1" logics
is automatically set to OFF.
OFF Disabled function.
-
Logic 2 (lg2) [ OFF ]
ON
Output for terminal 6-7 when acting as flashing light (24V 3W max
light connection).
OFF Output for terminal 6-7 when acting as electric lock.
7) AUTOSET MENU
This is used for automatic setting of the motor torque.
WARNING!! The autoset operation is only to be carried out after checking
the exact door movement (opening / closing) and correct limit switch inter-
vention.
As soon as the OK button is pressed, the following message will be displayed
".... .... ....", and the control unit initiates an opening manoeuvre followed by
a closing manoeuvre, during which the minimum torque value needed for
door movement is automatically set.
14 -
HYDRA-R - Ver. 05
INSTALLATION MANUAL
During this phase, it is important to avoid obscuring the photocells, as well
as using the START and STOP commands and the display.
At the end of this operation, if autoset is successfully completed, the con-
trol unit displays an "OK" message, and after any key has been pressed, it
returns to the autoset menu.
Otherwise, if the control unit displays a "KO" message, it means that the
autoset procedure has not been successfully completed; it is therefore ne-
cessary to check the wear condition of the overhead door and the regular
door movement, before proceeding to a new autoset operation.
WARNING! During the autoset phase, the obstacle detection function is
not optimised; therefore the installer must check the operator movement
and prevent persons and things from coming near or stopping within the
operating range.
In the case where battery back up is used, the autoset procedure must be
carried out with the control panel supplied by the power mains.
WARNING: Check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
8) INTEGRATED RECEIVER TECHNICAL SPECIFICATION
Receiver output channels:
-
output channel 1, if activated, controls a START command.
-
output channel 2, if activated, controls the excitation of the 2nd radio
channel relay for 1s.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with

ANTENNA INSTALLATION

Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a
more suitable position.
9) RECEIVER CONFIGURATION
The on-board receiver combines characteristics of utmost safety in copying
variable code (rolling code) coding with the convenience of carrying out
transmitter "cloning" operations thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be automatically
included within the list of the transmitters memorised in the receiver, either
as an addition or as a replacement of a particular transmitter.
Cloning by replacement is used to create a new transmitter which takes
the place of the one previously memorised in the receiver; in this way a
specific transmitter can be removed from the memory and will no longer
be usable.
Therefore it will be possible to remotely program a large number of additional
transmitters or, for example, replacement transmitters for those which have
been lost, without making changes directly to the receiver.
When coding safety is not a decisive factor, the on-board receiver allows you to
carry out fixed-code additional cloning which, although abandoning the variable
code, provides a high number of coding combinations, therefore keeping it
possible to "copy" any receiver which has already been programmed .
PROGRAMMING
Transmitter storage can be carried out in manual mode, or by means of the
UNIRADIO (Fig.4) programmer which allows you to create installations in
the "collective receivers" mode, as well as manage the complete installation
database using the EEdbase software.
10) MANUAL PROGRAMMING
In the case of standard installations where advanced functions are not
required, you can proceed to manual storage of the transmitters, making
reference to fig. B for basic programming.
-
If you wish the transmitter to activate output 1 (START) by means of key1,
key2, key3 or key4, enter the transmitter in menu "Start key", as in fig.
B.
-
If you wish the transmitter to activate output 2 (2nd radio channel relay)
by means of key1, key2, key3 or key4, enter the transmitter in menu "2nd
ch. key", as in fig. B.
Note: Hidden key P1 appears differently depending on the transmitter mo-
del.
For transmitters with hidden key, press hidden key P1 (fig. B1). For transmit-
ters without hidden key, the key P1 function corresponds to simultaneously
pressing the 4 transmitter keys or, after opening the battery compartment,
bridging the two P1 points by means of a screwdriver (fig. B2).
.