Energy-Efficient Operation
7.1.1

Setting examples

Standard external air temperature in °C
Required flow temperature
(at standard design temperature)
Temperature spread flow/return flow
Required return temperature
(at standard design temperature)
Setting for end point
of heating curve
A heat distribution system (e.g. underfloor heating) is
dimensioned for a maximum flow temperature at a particular
standard external temperature. This is dependent on the location
of the heat pump and is between -12 and -18 °C in Germany.
The max. return temperature that is set on the heating controller
must be entered for an external temperature of –20 °C. This is
done by entering the maximum return temperature for the given
standard external temperature in Fig. 7.2 on p. 23. The setting at
–20 °C can be read using the set of curves.
Fig. 7.2:
Heating curves to calculate the max. return set temperature
Underfloor heating
35 °C / 28 °C
-12
-14
-16
-12
35° C
35° C
35° C
55° C
7° C
7° C
7° C
10° C
28° C
28° C
28° C
45° C
30° C
29° C
29° C
48° C
Example 1
NOTE
Step 1:
Adjust the heating curve to suit the respective building and local
conditions by setting the gradient (heating curve end point).
Step 2:
Set the desired temperature level via a parallel shift of the heating curve
upwards or downwards (indicator bar).
Radiators
55 °C / 45°C
-14
-16
55° C
55° C
10° C
10° C
45° C
45° C
47° C
46° C
Example 2