6.1
EN-14
System-specific parameters
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
All settings to raise the heating characteristic
curve of heating circuit 2/3
Sets the time during which the temperature in
heating circuit 2/3 is to be raised.
Sets the temperature value by which the
heating characteristic curve of heating circuit 2/
3 is to be raised when the temperature is
raised.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is raised.
Operations to raise the temperature that
exceed a week day are activated or deactivated
at the end of each day accordingly.
Settings for cooling operation
Has the system got dynamic cooling (fixed
return set temperature)?
Sets the desired return set temperature when
dynamic cooling is selected
Has the system got silent (dew point-controlled)
cooling?
Are 1 or 2 room climate control stations
connected for silent cooling regulation?
Sets the room set temperature for silent cooling
The actual value is measured by room climate
control station 1
Rise in the minimum flow temperature
calculated from the measured values from the
room climate control station during silent
cooling. A raised value reduces the risk that
condensate will form.
Setting to specify whether a second chiller is to
be used in the system.
Setting for the external temperature below
which the cooling operation is terminated in the
case of rev. brine heat pumps or passive
cooling.
Sets DHW preparation
For heat pumps with 2 compressors, this sets
the external temperature below which DHW
preparation is carried out with 2 compressors
The hysteresis of the hot water set temperature
forms the neutral zone below which a request
for domestic hot water will be issued.
Setting range
Display
N
Heating circuit 2
T1
T2
Y
Heating circuit 2
00:00
Heating circuit 2
...
23:59
0 K
Heating circuit 2
...
19 K
N
Heating circuit 2
T1
T2
Y
Cooling function
No
Cooling function
Yes
10° C
Cooling function
... 15° C ...
Dyn. cooling
30° C
Yes
Cooling function
No
1
Cooling function
2
Silent cooling
15.0° C
Cooling function
... 20.0° C ...
Silent cooling
30.0° C
1.5 K
Cooling function
... 2.0 K ...
Silent cooling
5.0 K
No
Cooling function
Yes
-20° C
Cooling function
... 3° C ...
Brine heat pump
35° C
Domestic hot water
-30° C
Domestic hot water
... -25° C ...
2 Compressors
35° C
Nonreversible HP
(10° C HT)
2 K
Domestic hot water
...
Sensors
15 K