System-specific parameters
The following heating regulation options are
available for heating circuit 1:
* Return temperature regulation based on the
external temperature and the set heating curve
* Return temperature regulation via a fixed-
setpoint (horizontal heating characteristic
curve)
* Return temperature regulation based on the
room temperature in a reference room
The heating curve end point should be set
according to the design of the heating system.
This should be done by entering the maximum
return temperature, which is the product of the
maximum calculated flow temperature minus
the temperature difference in the heating
system (spread).
Sets the desired return set temperature when
fixed-setpoint regulation is selected
Sets the desired room set temperature and I
ratio when room temperature regulation is
selected
Sets the minimum return temperature when
room temperature regulation is selected
Different maximum temperatures are
permissible for panel and radiator heating
systems. The upper limit of the return set
temperature can be set between 25 °C and
70 °C.
The return set temperature hysteresis forms
the neutral zone for operation of the heat pump.
If the temperature "Return set temperature plus
hysteresis" is reached, the heat pump switches
itself off. If the temperature "Return set
temperature minus hysteresis" is reached, the
heat pump switches itself on.
Settings to lower the heating characteristic
curve of heating circuit 1
Sets the time during which the temperature in
heating circuit 1 is to be lowered
Sets the temperature value by which the
heating characteristic curve of heating circuit 1
is to be lowered when the temperature is
lowered
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
Settings to raise the heating characteristic
curve of heating circuit 1
Sets the time during which the temperature in
heating circuit 1 is to be raised.
Setting range
Display
External
Heating circuit 1
temperature
Room temperature:
Fixed-setpoint
Not bivalent-
Room temperature
renewable.
Not heating circuit 3
silent cooling
20° C
Heating circuit 1
... 30°C ...
Regulation according
to external
70° C
temperature
15° C
Heating circuit 1
... 40°C ...
Heating circuit 1
fixed-setpoint
60° C
15.0 °C / 001
Heating circuit 1
... 20.0 °C .../ ...60 ...
Heating circuit 1
reference room
30.0 °C / 999
15° C
Heating circuit 1
... 20°C ...
Heating circuit 1
reference room
30° C
25° C
Heating circuit 1
... 50°C ...
70° C
0.5 K
Heating circuit 1
... 2K ...
5 K
Heating circuit 1
00:00
Heating circuit 1
...
23:59
0 K
Heating circuit 1
...
19 K
N
Heating circuit 1
T1
T2
Y
Heating circuit 1
00:00
Heating circuit 1
...
23:59
or