Sun threshold regulator:
Twilight threshold regulator:
Glass breakage function:

Function of the sensor

The sensor lets you protect your plants and furniture from excessively strong
sunlight. If the sun threshold is exceeded, the shading solution automatically
comes down until the sensor is shaded, then stops and travels above the
sensor.

Setting mode

In setting mode you can adjust the sun and twilight thresholds with the help of
the indicator lamp.
The thresholds are displayed by the indicator lamp as follows:
Indicator lamp
Sun protection func-
tion / twilight function
Sun protection function
The sun threshold is preset to a medium value.
The sun threshold can be adjusted between heavy cloud (Position 1) up to dir-
ect sunshine. In Position 0 the sun protection function is switched off (the in-
dicator lamp flashes yellow 8 times).
Sun threshold exceeded for more than 3 minutes → shading solution comes
down.
Light intensity is below the sun threshold for more than 15 minutes → shading
solution comes up.
20 - en

Factory default settings

Explanation of functions

Green
Is executed
Position 5
Position 0 (deactivated)
off
Red
Is not executed