DGPW 0.0A 19.87V
001:54
0.0W
5> BRUSHED MOTOR DRIVE
BE CAREFUL :
Connect your brushed motor to the charger ONLY AFTER havinh selected this function on screen.
Always plug the motor off before leaving this function.
You can easily break-in new bushed electric motor using a variable voltage and running time. With this
function you also check the motor performance to optimize your power-train. The break-in process is
essential for maximizing the power of a new brushed motor. New motors have square brushes which press
up against the curved cpmmutator. The goal for the break-in process is to gentle shape the brushed so
that they develop a curved surface that fits snugly against the commutator giving greater conducting
surface area and hence lower losses and higher effciency.
5>Brushed Motor
Drive
---->
MOTOR
DRV
30min
2.0A
12.00V
- Test time: 1 to 90 minutes
- Current: 0,1 to 20A
- Test voltage: 1 à 15V
MOTOR 0.0A 19.78V
DRV
000:43
0.0W
MOTOR 0.0A 19.78V
STOP000:00
0.0W
6> HOT WIRE FOAM CUTTER DRIVE
In this mode, the charger acts as a convenient power supply for a hot wire foam cutter.
6>Hot Wire Foam
Cutter DRV
---->
FOAM CUT
30min
2.0A
12.00V
- Running time: 0 à 90min
- Current: 0,1 à 20A
- Voltage: 1 à 40V
16
Please press "Start/Enter" button for more than 3 seconds, and this screen
displays the current, voltage and test time of digital power (Max. power: 80W).
Press « Start/Enter » button.
The value in the right side of the first line sets the test duration in minutes.
The second line shows the upper limit of current on the left and drive voltage
on the right. After setting the current and voltage Press "Start/Enter" for
more than 3 seconds to start the new process. A beep tone will sound.
Status display. The top line shows the drive current and voltage. The second
line shows the output capacity (mAh) and in the lower right corner alternately
displays the output power or total run time.
You can stop the test at any time by pressing "Start/Enter".
Press « Start/Enter » button,
The value on the right side of the first line sets the test duration in minutes.
The second line shows the upper limit of current on the left side and drive
voltage on the right. After setting the current and voltage press "Start/Enter"
for more than 3 seconds to start the next process. A beep tone will be sound.