Télécharger Imprimer la page

Konect multi80+ Mode D'emploi page 12

Publicité

Les langues disponibles

Les langues disponibles

cHargE-to-DiScHargE & DiScHargE-to-cHargE cycLE niMH/nicD BattEry
NiMH CYCLE
DCHG>CHG
3
NiMH 1.0A
7.42V
D>C 022:45 00890
DCHG 1 1314mAh
CHG
1 1430mAh
pB (LEaD-SULpHUric aciD) BattEry prograM
This is programmed for charging Pb (lead-acid) battery with nominal voltage from 2 to 20V. Pb batteries are totally
different from NiCd or NiMH batteries. They can only deliver relatively lower current compare to their capacity,
and similar restrictions definitely apply to charge. So the optimal charge current will be 1/10 of the capacity. Pb
batteries must not be charged rapidly. Always follow the instruction is supplied by the manufacturer of battery.
When you are willing to alter the parameter value in the program, press Start/Enter key to make it blink then change
the value with INC or DEC key. The value will be stored by pressing Start/Enter key once.
cHarging pB BattEry
Pb Charge
4.0A
12.0V(6P)
Pb-6 4.0A
12.59V
CHG
022:43 00682
The audible sound indicates you at the end of the process.
DiScHarging pB BattEry
Pb DISCHARGE
1.0A
12.0V(6P)
Pb-6 0.4A
12.59V
DSC 022:43 00682
To stop discharging press Batt type/Stop key once. The audible sound indicates you at the end of process.
12
Set the sequence on the left and the number of cycle on the right. You can use this
function for balancing, refreshing and break-in the battery. To avoid rising temperature
of the battery, there will a brief cool-off period that already fixed at "User setting" after
each charge and discharge process. The cycling number ranges from 1 to 5.
To stop the process, press Batt type/Stop key once. You can change the
discharge or charge current by pressing Start/Enter key once during the
process. The audible sound indicates you the end of process.
At the end of the process, you can see charged or discharged electric capacities of
the battery at each cyclic process.
By pressing INC or DEC button, the screen shows the result of each cycle in order.
Set up the charge current on the left and the nominal voltage of the battery on
the right. The charge current ranges from 0.1 to 8.0A and the voltage should
be matched with the battery being charged.
Start the charge process by pressing Start/Enter key for more than 3 seconds.
The screen displays the state of charging process. To stop charging forcibly,
press Batt type/Stop key once.
Set discharge current on the left and final voltage on the right. The discharge
current ranges from 0.1 to 2.0A.
To start the process, press Start/Enter key for more than 3 seconds.
The screen displays the current state of discharge. You can alter the
discharge current by pressing Start/Enter key during the process. Once you
change the current value, store it by pressing Start/Enter button again.

Publicité