Solution Of Possible Problems - Astralpool 73082 Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

7. SOLUTION Of POSSIBLE PROBLEMS.

We attach a list of possible problems that can occur with the valve, together with the best solution. If the
MODBUS communication bus is used, please consult the specific manual to solve the possible incidents.
PROBLEM
The valve does not start up
and the LED is not lit up.
The LED is lit but the
backwash does not start.
The actuator does not work
and the LEDs flash once.
The actuator does not work
and the LEDs flashes twice.
The actuator does not work
and the LEDs flash 3 times.
The actuator does not work
and the red light flash 4
times.
The actuator does not work
and the LEDs flash 6 times.
The buttons on the keypad
do not work.
The valve does not work and
the fuse has blown.
CAUSE
Incorrect electrical
connection
Incorrect electrical
connection
Failure in filtration position
microswitch or the motor
does not turn.
Failure in any position
microswitch except for the
filtering one.
Failure in the ratchet
microswitch.
The valve distributor is
blocked.
Problem with the
distributor ascend micro.
The connecting cable is
disconnected.
There is an incorrect
electrical connection
producing an excessive
level of power
consumption at terminal
J10 (4-5) of the valve.
16
SOLUTION
Check the power supply connection
Check the connection cables between
the main electronic board and the
auxiliary one.
Contact technical assistance or request
a spare part for the motor unit.
Contact technical assistance.
Contact technical assistance.
DISCONNECT THE POWER SUPPLY
AND TAKE OFF THE ACTUATOR. Take
off the valve lid, clean the distributor
and apply grease to the shaft and the
o'rings (TURMSILON GL320 grease).
RESTART THE VALVE'S POWER SUPPLY
FOR A FEW SECONDS OR RESTART
THE ERROR INDICATION (4.7). IF
THIS PERSISTS, CONTACT TECHNICAL
ASSISTANCE.
Check that it is correctly connected.
Measure the power supply in the 4-5
connection and review the electrical
installation. Change the fuse when
the connection problem is solved (it is
delivered as a spare part).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

73082-9000

Table des Matières