english
likely to be ingested into the nailer. If any
portion of a nail is ingested into the tool,
the nail should be retrieved by removing
the top cap.
NOTE: The jam could be as a result of debris build
up in the nose channel. Please check and clear
out any debris as outlined below immediately if you
notice any change of performance in the tool.
1. Remove battery pack from tool and engage
trigger safety lock-off (B).
2. After laying the tool on its side, slide the
spring-loaded pusher latch (H) to the base of
the magazine to lock it into place and unload
nail strip.
NOTE: If nails don't release press nail support
lever (N).
3. Using the hex tool (K) provided, loosen the two
hex bolts (Q) at the top of the magazine.
4. Rotate the magazine (G) forward.
5. Remove jammed/bent nail, using pliers if
necessary. Clear out any debris in the nail
channel if required.
CAUTION: If any portion of a nail is
ingested into the tool, the nail should be
retrieved by removing the top cap. Refer
to Figure 11 a, b, d, e.
6. If driver blade is in the down position, rotate
the stall release lever (F) on the top of the
nailer.
NOTE: If the driver blade will not reset after
rotating the stall release lever, manually resetting
the blade with a long screwdriver may be
necessary.
7. Rotate the magazine back into position under
the nose of the tool and tighten hex bolts (Q).
8. Reinsert battery pack.
NOTE: The tool will disable itself and not reset
until the battery pack has been removed and
reinserted.
9. Reinsert nails into magazine (refer to Loading
the Tool).
10. Release the pusher latch (H).
11. Disengage the trigger safety lock-off (B) when
ready to continute nailing.
If nails become jammed in the nosepiece
frequently, have the tool serviced by an authorised
D
WALT service centre.
e
56
All manuals and user guides at all-guides.com
MAINTENANCE
Your D
operate over a long period of time with a minimum
of maintenance. Continuous satisfactory operation
depends upon proper tool care and regular
cleaning.
The charger and battery pack are not serviceable.
Lubrication
Your power tool requires no additional lubrication.
Cleaning
CHARGER CLEANING INSTRUCTIONS
WALT power tool has been designed to
e
WARNING: To reduce the risk of
serious personal injury, turn tool
off and disconnect battery pack
before making any adjustments or
removing/installing attachments or
accessories. An accidental start-up can
cause injury.
NOTICE: NEVER spray or in any other
way apply lubricants or cleaning solvents
inside the tool. This can seriously affect the
life and performance of the tool.
WARNING: Blow dirt and dust out of
the main housing with dry air as often as
dirt is seen collecting in and around the
air vents. Wear approved eye protection
and approved dust mask when
performing this procedure.
WARNING: Never use solvents or
other harsh chemicals for cleaning the
non-metallic parts of the tool. These
chemicals may weaken the materials
used in these parts. Use a cloth
dampened only with water and mild
soap. Never let any liquid get inside the
tool; never immerse any part of the tool
into a liquid.
WARNING: Shock hazard. Disconnect
the charger from the AC outlet before
cleaning. Dirt and grease may be
removed from the exterior of the charger
using a cloth or soft non-metallic brush.
Do not use water or any cleaning
solutions.