6.10 Coolant compound table
6.11 Weight
OM 803 us – Edition 3.7 * 803b610.fm
1
Outside temperature
Up to °C (°F)
−37 (−34.6)
1.
Use the 1:1 concentration for warm outside temperatures, too, to ensure protection against corrosion, cavitation and deposits.
2.
Do not mix the coolant with other coolants.
803 without rollbar
1
Operating weight
2
Transport weight
803 with rollbar
1
Operating weight
2
Transport weight
1.
Operating weight: basic machine + full fuel tank + backhoe bucket (250 mm/10 in) + operator (75 kg/165 lbs).
2.
Transport weight: basic machine + 10 % fuel capacity.
Information!
The actual machine weight depends on the selected options and must be read off the
type label.
Add the weight of all subsequently installed equipment to the weight of the machine.
Weight indications can vary by +/− 2 %.
Technical data
2
Water
Coolant
% by volume % by volume
50
50
1032 kg (2,275 lbs)
935 kg (2,061 lbs)
1087 kg (2,396 lbs)
990 kg (2,182 lbs)