Operation
Changeover from HPU to diesel operation
Fig. 148:
7.5 kW version
9 kW version
R
Fig. 149:
Fig. 150:
B
1
Fig. 151:
1
0
2
Fig. 152:
3-68
Key A for changing over between HPU and diesel operation is located in the document
box behind the operator seat.
1
Stop the HPU: press the red push button (R)
R
2
Insert key A and turn it anticlockwise to position 1.
3
Remove key A and store it in the document box.
A
Indication B must be in position 1.
4
Start the diesel engine: turn the starting key to position 3.
3
NOTICE
Possible damage to the excavator if the diesel engine is started in the HPU
position.
• Stop the diesel engine and change over from HPU to diesel operation.
OM 803 us – Edition 3.7 * * 803b340.fm