RCD10.5
A
NOTICE! Damage hazard
• To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if
possible. For this reason avoid additional switches, plugs or power
strips.
• Before connecting check whether the operating voltage and the bat-
tery voltage correspond (see data plate).
• Ensure that the polarity is correct when connecting the
supply.
1. Determine the required cross section of the cable in relation to the cable length
according to fig. 4, page 5.
2. Connect the cables to the AMP connector of the refrigerator (fig. 5, page 5).
3. Connect the other ends of the cables to the
– rd (red): with a fuse protection (10 A) fitted to the positive (+) pole
– bk (black): to the negative (–) pole
4.4
Securing the refrigerator
A
NOTICE! Damage hazard
Only screw through the bushings provided, otherwise foamed compo-
nents, such as cables, can be damaged.
I
NOTE
• Attach the side walls or the attached strips so that the screws are
tight, even under increased loads (while driving).
• The refrigerator is designed to provide a regulated air flow. It is not
recommend to leave additional space between the refrigerator and
the recess walls.
1. Move the refrigerator into its final location with the front flange sitting tight
against the recess front.
2. Fasten the screws (fig. 6, page 6) through the plastic bushings in the sides of
the refrigerator, and further into the wall.
3. Put the caps onto the screw heads.
EN
Installing the refrigerator
power supply:
12 Vg
power
12 Vg