Télécharger Imprimer la page

HOESCH Comfort Serie Instructions D'installation Et D'utilisation page 31

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Fig. 6.5.
Function keys
M
L
P
R
In this group, there are keys to switch on or off other devices such
as the ventilator, scent dispenser, or to start descaling.
Key L – switching to time display. Using keys J and K , the time
indicated in the display can be increased or reduced
by 5 minutes each time (and during the bath every 1
minute, only after the fi rst time the desired temperature
set is reached). Time setpoint "--": the generator works
in continuous mode, after 4 hours of operation it will
perform fl ushing process.
Key M – switching to temperature display. If the key is
pressed one more time, it will display the set or
current temperature. By pressing keys J and K , the
temperature indicated on the display can be increased
or reduced in the range from 30 °C to 50 °C (every 2ºC).
The bath time is counted from the moment when the
desired temperature is reached inside the cabin.
Key N – Pressing – switching on the lighting
Pressing again – changing the light colour / changing the
program (as shown in the overview)
Holding the key - switching off the light
The light is switched off automatically 20 minutes after
the generator is switched off.
Program Meaning
1
white
2
red
10
3
orange
4
yellow
5
green
9
6
blue
7
indigo
8
purple
9
rotating
10
energy
11
relax
Key P – start of scent dosing process
R key – start-up of the ventilator connected to the "Went" input
of the controller (see Fig. 5). The ventilator can be started at any
time. The fan can be switched off manually using this key or it
will switch off automatically after 10 minutes of operation. The
operating status of the fan is determined by the LED associated
with this key.
N
S
1
2
11
3
4
8
5
7
6
Key S – Start of the descaling process. The descaling process
can only be started if the steam bath is switched off (the LED
is off). Hold down this key until you hear a continuous beep:
the display will show the number of hours of steam bathing
since the last descaling. An additional condition for starting the
descaling process is a suffi cient amount of descaling agent in
the external tank, to which a liquid level sensor is connected, e.g.
PVC-02. when the device is off, LED F may flash. This means
that descaling must be carried out or that it will be carried out
automatically after 90 minutes of inactivity since the last
shut-down. During the desclaing, the display shows the digits
indicating the subsequent stages and LED F is lit.
12
Start-up of the device
Before the start-up of the device by pressing key H the following
can be set.
1.
Steam bath temperature – key M
2.
Bathing time – key L
3.
Switch on the lighting by pressing key N
4.
Switch on the ventilator – key R
5.
Start descaling – key S
If pressing key H does not start the steam bath and indicator
Slights up during pressing, the generators must fi rst be descaled
(key S – function keys). When the steam bath (key H) is activated,
the displayed bath time will only be measured once the tank has
been fi lled with water. During fi lling, the display fl ashes with zero.
The steam bath time can be set to 90 minutes with the steam bath
at 5-minute intervals. The setting "--" causes continuous operation
of the device, without any time limit. After 4 hours of operation
of the steam generator, the water tank is automatically emptied.
The generator is fl ushed and refi lled. The process lasts about 5
minutes. During operation, pressing the temperature key (key M)
causes displaying two values alternately: the current temperature
and the set temperature. The desired temperature is displayed
with a dot. It can be changed during the bath.
13
Air-input blower (optional)
The Air-input blower is automatically switched on with a steam
function. The switch-off is also automatic: 3 minutes after the
steam bath has ended. The use of a Air-input blower optimises
the distribution of steam in the steam cabin.
14
Descaling
The steam generator must be descaled regularly.
The descaling process is automatic or manual.
The automatic descaling process starts after 8 hours of generator
operation (factory setting), 90 minutes after the end of generator
operation.
The need to perform the descaling process begins to be indicated
by the system (fl ashing diode "S") 2 hours before the end of 8
hours of the generator's operation. After 8 hours of operation,
the system will not allow to turn on the generator (keypad lock)
without performing the descaling process.
Automatic descaling is possible after connecting a tank with a
suitable agent based on citric acid (we recommend a special
descaling agent from Hoeschbrand to steam generators Item
no. 120248). The device starts automatic descaling after 90
minutes of inactivity.
To determine the minimum necessary frequency of descaling,
the water hardness must be determined by your water supplier
(recommended) or you must carry out a water hardness test
yourself:
a)
using paper testers (e.g. Aquadur),
b)
with droplet testers (e.g. TITRANT) according to the
manufacturer's recommendations
To switch on the descaling process, place the end of the peristaltic
pump hose in the desclaing tank (Fig. 2), then press and hold
key S until you hear a continuous beep. Make sure that there
GB
31

Publicité

loading

Ce manuel est également adapté pour:

Comfort 6Comfort 12Comfort 21682306823168232