HOESCH Comfort Serie Instructions D'installation Et D'utilisation page 30

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Manual
WARNING: Children may only operate the device
unattended if appropriate instructions have been
provided to enable the child to use it safely and to
understand the danger of misuse.
11
Control panel operation
The control panel consists of keys and LEDs arranged in groups
and an LED display.
1.
Blocking and malfunctioning indication
2.
Display group
3.
Interrupter and setting keys
4.
Function keys
Fig. 6.1.
Control panel operation
1
2
GB
3
4
Blocking and malfunctioning indication.
Fig. 6.2.
Blocking and malfunctioning indication
A
There are three LEDs in this group.
LED A is the general malfunction indicator and lights up when one
of the following situations occurs:
Icon "E1" damage to the temperature sensor of water in the
water tank
Icon "E2" no descaling agent.
Icon "E3" cabin temperature sensor damaged or not connected.
Icon "E4" the device does not fi ll with water.
Icon "E5" drain valve damaged or clogged
Icon "E6" an error occurred during descaling procedure
LED B is lit when the generator is switched on and the input ON
on the control PCB (see Fig. 5) is open (External switch).
30
B
C
If a coin-operated device or a similar service access system
is connected to this input, the LED indicates that the device is
locked.
LED C is lit when the bath door is open. There is a "Door" input
on the controller board (see Fig. 5), which automatically switches
off steam generation after 5 minutes when it is open.
Function keys
Fig. 6.3.
Display
D
E
F
In this group, LEDs are used to indicate the volume shown on the
display.
LED D – Advanced settings – see section 05.
LED E – the steam bath time is displayed. If the LED is on, the
time set by the user is shown. During operation, the LED switches
off every 1 second.
LED F – the current temperature is displayed. If the LED is on,
the user's set temperature is displayed.
Display G – two-digit LED display.
Interrupter and setting keys
Fig. 6.4.
Interrupter and setting keys
H
In this group there is a main switch (H) and keys (J and K), with
the use of which it is possible to change some parameters, e.g.
time of bath or temperature. The switch is associated with a diode
that lights up when the device is on. Keys J and K are used to
increase and decrease the parameter displayed on the display
accordingly.
Every time the steam bath is switched off, the generator drains
off automatically after 60 minutes. Then a fl ush takes place. The
procedure lasts about 5 minutes. After the steam bath has been
switched off manually (before the set operating time has elapsed
or during continuous operation – time setting "0"), the emptying
and fl ushing process can be started manually.
During the fl ushing procedure, the display shows the symbol "PL".
G
J
K