2.4.3 INSTALLING THE OUTLET PIPES
DIAMETER VENT PIPE OUTLET DIRECTION
110 mm
110 mm
110 mm
35 mm
40 mm
!
280
415 mm
NOTE!
The appliance flue terminal is designed for connecting 110 mm PP quality pipes with an
inner diameter of no less than 102 mm. The pipe is to enter 35 mm into the toilet flue
terminal. Do not use excessive force when connecting the pipe, as this may damage the
appliance.
Horizontal flue pipe
Vertical flue pipe
Vertical flue pipe
C
Ø 111mm
155mm
REFERENCE
BENDS
C
(Not allowed)
A
None
B
2 x 45° bends
C
NOTE!
When adjusting the pipe length, please notice
that the pipe will enter 35 mm into the appliance
flue terminal, and will have to be
calculated into the planning of your installation.
NOTE!
When installing the pipe vertically, straight up
from the appliance, please notice that the
minimum distance from the wall to the toilet
must be 280mm.
NOTE!
The Original Cinderella Installation Kit includes
1015 mm pipes to be used on the outlet instal-
lation, the pipes are delivered with socket and
gasket for simple installation. When
installing the pipe on the outer wall, you will have
to enter the pipe from the external to the inside.
MAXIMUM PIPE LENGTH
1000 mm
6000 mm
5000 mm
NOTE!
The center of
the appliance
flue terminal is
415 mm from
the floor level.
9