2.4 INSTALLATION SPECIFICATIONS
2.4.1 SPECIFICATIONS PARTS AND MATERIALS
ITEM
Ventilation pipes
Elbow (Outlet air)
Flue Terminal Cap
NOTE!
2.4.2 INSTALLING THE CINDERELLA INCINERATING TOILET
It is essential to ensure proper ventilation in accordance with the guidelines in this manual to guarantee the
functionality of your new Cinderella toilet. Improper installation may cause malfunction, wear or odors and will
void the warranty. Read each section carefully before starting the installation of the toilet. Always make sure that
the work is carried out by professionals in accordance with local regulations.
CAUTION!
The Cinderella Comfort toilet must have its own outlet air pipe and it is not permitted to
install Cinderella Comfort ventilation with the use of the following:
CAUTION!
WARNING!
Before cutting any holes, always check that you will not cut any electrical wiring or water
pipes.
8
SPECIFICATIONS
Cinderella Comfort is required to be installed with 110 mm pipes with a smooth
inner surface and a minimum inner diameter of 102 mm. The pipe material must
be specified for temperatures over 100° C and preferably of a PP- or CPVC- type. We
strongly recommend using the Original Cinderella PP- quality pipes.
Cinderella Comfort is required to be installed with a smooth curved elbow that
minimizes the restriction of the air flow. We strongly recommend using the Original
Cinderella Elbow 87° w/ drain.
Cinderella Comfort is required to be installed with a flue terminal cap that prevents
intrusion of rainwater and that has a minimum restriction of the air flow. Wind
fans or similar is not to be used when venting the Cinderella Incinerating Toilet. We
strongly recommend using the Original Cinderella Flue Terminal Cap.
The inside of the ventilation pipe must be smooth and not embossed or grooved.
The elbow must be accessible when installed, so that the drainage pipe can be rinsed,
and the outlet pipe cleaned.
Cinderella Comfort is proved for use in bathrooms/wet rooms (IP 34 classified), but
water must not be splashed over the external parts of the toilet.
The toilet must be placed on a firm and level base and your Cinderella appliance may
be installed on a heated floor
Wind fan or similar as a replacement for the chimney cap
Flexible ducts or pipes.
Pipes with inner diameter less than 102 mm.
Other 90° bends in addition to the elbow bend.
Never use a mesh net in the ventilation pipe as this will restrict the airflow in the system.
Upon installation of the appliance, the technical and administrative regulations of the
country in which the toilet is installed must be adhered to. We recommend that you
contact your local dealer for planning and installing your Cinderella toilet.
If the pipe perforates the roof surface, ensure that it is in compliance with
building regulations.