NOTE!
The pipe must always be installed vertically above the
roof and extend at least 600 mm above the roof surface.
If the outlet air pipe is to be enclosed (e.g. using metal
siding), make sure that the end of the pipe extends at
least 400 mm above the enclosure.
If installed where snow is likely to accumulate it might
be necessary to extend the pipe further, and to secure
accordingly.
NOTE!
Cinderella supplies a specially designed "siphon" that fits
onto the elbow provided in the installation kit, this item
can be purchased as an accessory from any Cinderella
dealer. If installation is done from the interior, you will
need to connect the siphon to the elbow-piece to prevent
condensation and rainwater to drain onto the floor. Failure
to collect the condensation and emptying it regularly, may
result in damage to the floor.
2.4.4 INSTALLING THE HORIZONTAL INLET PIPE
It is important to ensure that the toilet has enough access to fresh air, and we therefore always recommend
installing the Cinderella Comfort with designated inlet air connection. Supplying fresh air from the outside and
into the appliance is essential for cooling, circulation and the supply of oxygen to the incineration process. If the
toilet has restricted access to air / oxygen, you will experience poor incineration, reduced efficiency and possibly
overheating of the appliance. Poor incineration over time will wear on the product and void your warranty.
OUTER DIAMETER
INLET PIPE
110mm
Ø 111mm
155mm
35 mm
40 mm
!
10
HEIGHT MIDPOINT
INLET PIPE
155 mm
INLET
DIRECTION
Horizontal
NOTE!
The center hight for the inlet air terminal is
155 mm from the floor level.
The Original Cinderella Installation kit in-
cludes 2 x 500 mm pipes to be utilized for the
inlet air and ventilation and flue terminal cap.
Adjust the length of inlet to fit he installation,
please notice that the pipe will enter 40 mm
into the inlet terminal on the appliance.
NOTE!
When mounting the storm collar on the external
wall, make sure that the pipe is installed flush
with the storm bottom of the storm collar.
Misplacement can lead to restricted air circulation
that cause poor incineration, reduced efficiency
and possibly overheating of the appliance.
MAXIMUM
PIPE LENGTH
1000 mm