4
Installation
Risk of injury!
Loose tubes may hit objects around them.
Tubes must be connected first to the unit.
Only press the foot switch after all tubes have been connected.
4.1
Unpacking
⇒ Take the unit and all the accessories out of the package�
⇒ Check to ensure all delivery parts are complete (compare "Included in Delivery")�
4.2
Setting up
⇒ Place the unit on a level and stable base�
4.3
Connect foot switch
The following tubes (30, 31) are already connected to the foot switch�
4.3.1
2 Tank version:
⇒ Push the tube marked „A" (30) as far as it will go into the tube
connection point „A" (13)�
⇒ Push the tube marked „B" (31) as far as it will go into the tube
connection point „B" (19)�
When inserting the tubes you will notice a slight resistance which
must be overcome�
4.3.2
1 Tank version:
⇒ Push the tube marked „A" (30) as far as it will go into the tube
connection point „A" (13)�
⇒ Push the tube marked „B" (31) as far as it will go into the tube
connection point „B" (22) (on sandblasting tank)�
When inserting the tubes you will notice a slight resistance which
must be overcome�
4.4
Compressed air connection
⇒ Push the compressed air tube (11) onto the tube connection
point (14) as far as it will go� In doing so there will be a slight
resistance to overcome�
⇒ Select the relevant hose connection piece from the enclosed
attachment set and fit it onto the end of the tube.
⇒ Attach to the compressed air network�