Télécharger Imprimer la page

Avdel Genesis G1 Manuel D'instructions page 7

Masquer les pouces Voir aussi pour Genesis G1:

Publicité

Les langues disponibles

Les langues disponibles

P u t t i n g i n t o S e r v i c e
A i r S u p p l y
All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators and filtering
systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to ensure maximum tool life and
minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced in the system or
10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured where
operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres or
Read daily servicing details page 11.
O p e r a t i n g P ro c e d u re
Ensure that a nose assembly suitable for the fastener is fitted as
described on page 8.
Connect the tool to the air supply.
Insert the fastener stem into the nose of the tool.
Insert the tool with the fastener squarely into the prepared hole
of the application.
Fully actuate the trigger. The tool cycle will broach the fastener.
Check that broken stems are being extracted to the rear of the
tool. If not, adjust the vacuum extraction rotary valve 57.
Item numbers in bold refer to the general assembly drawing and parts list on pages 16-17.
All manuals and user guides at all-guides.com
(USED DURING MAINTENANCE
OF FILTER/REGULATOR OR LUBRICATION UNITS)
3 METRES MAXIMUM
STOP COCK
8
PRESSURE REGULATOR
AND FILTER (DRAIN DAILY)
ADJUSTING THE VACUUM EXTRACTION
Using a screwdriver, turn rotary valve 57 until the air flow at
the rear of the tool ceases.
With the nose of the tool pointing downwards, insert a
fastener into the nose and hold it into position.
Turn the rotary valve either way until there is sufficient suction
to retain the fastener.
E n g l i s h
1
/
inch.
4
TAKE OFF POINT
FROM
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
7

Publicité

loading