P r i m i n g
P r i m i n g P ro c e d u re
DISCONNECT THE TOOL FROM THE AIR SUPPLY OR SWITCH OFF AT VALVE 53.
All operations should be carried out on a clean bench, with clean hands in a clean area.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
Remove bleed screw 7 and seal 8.
Connect air supply to tool and switch ON/OFF valve 53 to 'ON" position.
Invert tool over suitable container and actuate trigger. Waste oil will be ejected through the bleed screw hole.
CARE SHOULD BE TAKEN TO ENSURE THAT THE BLEED HOLE IS NOT DIRECTED TOWARDS THE OPERATOR OR OTHER PERSONS.
Screw stop nut 07900-00698 onto jaw spreader housing 1.
Disconnect air supply to tool or switch ON/OFF valve 53 to 'OFF" position.
Fill the priming pump with oil.
Screw priming pump 07900-00700 into the bleed screw hole with seal 8 in place.
Actuate the priming pump by pressing down and releasing several times until resistance is felt.
Remove the priming pump and the stop nut.
Replace bleed screw 7 and seal 8.
Connect air supply to tool and switch ON/OFF valve 53 to 'ON" position.
Check that the stroke of the tool meets the minimum specification of 14 millimetres. To check the stroke, measure the distance
between the front face of jaw spreader housing 1 and the front face of the head, BEFORE pressing the trigger and when the trigger is
fully actuated. The stroke is the difference between the two measurements. If it does not meet the minimum specification, repeat the
priming procedure.
Item numbers in bold refer to the general assembly drawing and parts list on pages 16-17.
All manuals and user guides at all-guides.com
I M P O R T A N T
REMOVE THE NOSE EQUIPMENT FROM THE TOOL.
Ensure that the new oil is perfectly clean and free from air bubbles.
E n g l i s h