Putting into operation
Putting into operation
Read the safety notes before ill putting into operation.
All protection and auxiliary equipment must be fitted.
After connecting to the mains, your scheppach Precisa 4.0
bench circular saw is ready for operation.
Working with the suction system
Fig."N"
The scheppach woova 3.0 suction system provides a prac-
tically dust-free working atmosphere in conjunction with
the schepppach Precisa 4.0 bench circular saw.
Adjusting the saw blade height
Fig."P"
• Continuous saw blade height adjustment from zero to
max. 82 mm is possible with the handwheel.
• Make adjustments to the saw blade height only when
the motor is switched off and the saw blade has
come to a standstill.
Adjusting the saw blade angle
Fig."Q"
• Continuous saw blade angle adjustment from 90m° to
max 45° is possible with the adjusting wheel.
• Loosen the wing nut on the adjusting wheel, select the
desired setting in degrees and tighten the wing nut
again.
• Make adjustments to the saw blade angle only when the
motor is switched off and the saw blade has come to a
standstill
Changing the saw blade
See assembly note in figs. C + D
Important:
Use only weil sharpened saw blades
which are free from cracks and distortion.
If the blade slot is damaged, renew the bench insert.
Caution!
Disconnect the mains plug when changing the saw blade.
All manuals and user guides at all-guides.com
All protection and safety devices must be replaced after
completing repair and maintenance procedures.
The following maintenance points should be observed for
your scheppach Precisa 4.0 bench circular saw.
Fig."R"
After the first 1 - 2 hours of operation, check the belt
tension and increase the tension.
• Remove the cover hood and splitting wedge.
• Lower the saw blade into the table top and then
• Turn overthe circular­saw bench onto the bench top. To
• Loosen the 4 motor fixing screws (1), but do not
• Turn the motor, with both hands, in the direction of the
• Retighten the motor fixing screws (1).
• Set the circular­saw bench up again, and complete
Regularly check the belt tension, and
retension
The moveable parts such as the threaded spindie for cutting
height adjustment and the toothed rack with
tooth segment for angle adjustmentshould occasionally be
cleaned and treated with a dry lubricant spray.
Longitudinal fence
• The top of the longitudinal fence guide tube and the
• Always keep the bench surface free frorn wood resin.
• In order to ensure trouble­free chip ejection, keep the
The installed electric motor is factory connected ready for
operation.
The connection made bythe customer as weil as any extensi-
on cables used must comply with all relevant regulations.
Maintenance
Switch off the motor and pull the ill plug
out before undertaking any maintenance work.
swivel 45°
protect the bench surface, lay cardboard or ablanket on
the ground.
unscrew them totally
arrow (2)
assembly.
bottom of the longitudinal fence guide slide should
be cleaned and treated with dry lubricant spray as
required (gleitmo 980 A)
protective casing free from wood chips and sawdust.
To do this, remove the bench insert and fold away the
cover oft the protective casing.
For cleaning remove the mains plug!
Electrical connection
A Connection and repair work on ill the
electrical equipment must be carried out by a
qualified technician only.