Télécharger Imprimer la page

Nilfisk Liberty SC50 UVGI Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
SKIRT REPLACEMENT
Bristle Skirt Removal
1. Remove the Bulb Housing from the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).
2. Remove the nine Screws (4) that secure the Plastic Cover (5) to the Bulb Housing (6).
3. Remove the fourteen Screws (7) and Nuts (8) that secure the Bristle Skirts (9) to the Plastic Cover (5).
4. Installation is the reverse of removal.
6
4
Inner Rubber Skirt Removal
1. Remove the Bulb Housing from the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).
2. Remove the nine Screws (4) that secure the Plastic Cover (5) to the Bulb Housing (6).
3. Remove the twenty-four Screws (10) that secure the Mounting Straps (11) which hold the Inner Rubber Skirts (12) to the Bulb
Housing (6).
4. Installation is the reverse of removal.
5. Reinstall the Bulb Housing onto the UVGI Frame Assembly (see Bulb Housing Assembly Removal and Installation).
6
7/2020
5
9
7
56091240 - Nilfisk Liberty SC50 UVGI
INSTRUCTIONS FOR USE
9
5
8
11
10
ENGLISH - A
9
7
12
A - 11
9

Publicité

loading

Ce manuel est également adapté pour:

56394506