10 Standard Delivery
1 Extraction box
EN
1 Operating instructions, with attachments
1 Power cord
1 Extraction duct, complete
1 Armrests, complete
11
Delivery Versions
No. 2626-0105 Dustex master plus 230 V, 50 / 60 Hz
No. 2626-1105
12 Accessories
No. 2626-0300 Magnifier with holder
13 Troubleshooting
Problem
Insufficient extraction
power.
Lamp does not switch
on.
Dustex master plus 100 - 120 V, 50 / 60 Hz
Possible cause
• Extraction duct blocked�
• Extraction grate blocked�
• Power cord not plugged in�
• Illumination defect�
• Faulty electronics�
The device with fluorescent tubes
• The fluorescent tube is not situated
correctly in the socket�
• Fluorescent tubes defect�
• Remove and clean the extraction duct�
• Remove and clean the extraction grate�
• Plug the power cord in�
• Change light using the service or see spare
part list�
• Have Customer Service replace the electron-
ics or refer to the Spare Parts List�
• Check that the fluorescent tube is fitted
correctly (see chapter 5�4�2)�
• Changing the fluorescent tubes (see chap-
ter 5�4�2)�
We reserve the right to make technical changes.
- 8 -