Operation; Setup - Titan PowrCoat Série Mode D'emploi

Masquer les pouces Voir aussi pour PowrCoat Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

4.
Operation
This equipment produces a fluid stream at extremely
high pressure. Read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
4.1

Setup

1. Make sure the siphon hose (fig. 5, 1) is connected to the fluid
section (2) and the bleed hose (3) is connected to the bleed
valve (4). They each have factory installed PTFE tape on the
male end of the hoses and should be wrench tight.
i
To orient the siphon hose, loosen the swivel (5) and
orient the siphon tube to the desired location.
4
2
5
1
2. Attach a minimum of 50' (15m) of nylon airless spray hose to
the sprayer. Do not use PTFE tape or thread sealant on the
spray hose connection.
3. Attach an airless spray gun to the spray hose. Do not attach
the tip to the spray gun yet. Remove the tip if it is already
attached.
a.
To use two guns, remove the plug from the second gun outlet
on the filter assembly. Connect a hose and gun to the outlet.
For multiple gun operation, connect a multiple gun
i
manifold to the single gun outlet. Connect a hose
and gun to each outlet. All connections that are not
used must be plugged.
3
GB
4. Fill the oil cup 1/2 full with Piston Lube (P/N 314-480). This
extends packing life.
Piston Lube prevents increased wear and tear to the
packings.
Attention
5. Verify that the air compressor meets the power requirements
necessary to effectively power the sprayer. See "Technical
Data", section 3.4 to determine air requirements.
i
The requirements will vary on each model.
6. Prior to connecting the compressor to the unit, perform the
following in order to prevent accidental startup:
a.
Close the shutoff valve (fig 7, item 1). The figure shows the
handle in the closed position.
b.
Turn the air regulator (2) fully counterclockwise to its lowest
pressure setting.
c.
Open the bleed valve (3) by turning it fully counterclockwise.
7. Using a wrench, remove the red plug from the air hose fitting
(Fig. 8, item 1). Attach the air hose and tighten wrench tight.
All units are equipped with a 3/4" NPT (M) air hose fitting.
Proper earthing (grounding) is important. The
passage of some materials through the nylon fluid
hose will build up a static electric charge, which if
discharged, could ignite solvent vapors present and
create an explosion.
8
1
2
3
1
PowrCoat

Publicité

Table des Matières
loading